CHASSIS 19"

CHASSIS 19" 1U ou 2U pour cartes Crystal Vision


Ajouter article au devis

 

 

Indigo 2SE

MECHANICAL DIMENSIONS

2U 19" rack unit. Height 89mm, width 482mm, depth 425mm

Indigo 2SE: Empty weight 3.63kg. Maximum loaded weight 7.4kg

Indigo 2AE: Empty weight 3.84kg. Maximum loaded weight 7.6kg

POWER REQUIREMENT

90-264VAC, 47-63Hz

POWER SUPPLIES

The 2U frames have plug-in power supplies fitted which are ordered separately

Indigo 2AE/2SE take one or two 160W PSU-160i power supplies

Optional power redundancy is available

The PSU-160i has an on-board processor to report to the frame both PSU status and PSU fan status

FRAME REAR MODULES

Crystal Vision offers a wide choice of rear modules which slot on to the back of the frames

Available with BNCs, D-Type, 'easywire' DIN 41612, RJ45 and optical connectors

Single slot, double slot and quad slot rear modules can be used in 2U frames

Rear modules are individually retained by two screws

OPERATING CONDITIONS

0 to 40°C non-condensing

Indigo 2SE CoolFlow frame: Ventilation front to sides/rear, without air filters

Indigo 2AE frame: Ventilation front to front, without air filters

FRAME OPERATING SOFTWARE

The AE and SE frames run uCLinux which allows the use of standard software such as an SNMP Proxy Agent

FRAMES MONITORING

The frames monitor and report frame fan status and temperature

If any parameter should fall outside its range, the frame status will indicate a fail condition on both the front panel indicators and by the change over relay contacts accessible from the rear interface connectors. The fail condition will also be diagnosable via Statesman or SNMP

REMOTE CONTROL

Six control lines per module. Assigned on module (eg. GPI or RS422/RS232)

Contact open/closure for any power supply or frame fault condition (supply out of range or failure, fan too slow or fail, over-heat)

RS485 loop system from front panel to all modules and rear connection (rear connection by way of 26-pin high density D-Type connector and RJ45 connector)

Allows Ethernet connection to a PC running Statesman

SNMP monitoring and control available as a frame option. 'AE' and 'SE' frames are preinstalled with an SNMP manager which will require a licence to be downloaded and installed